110KV S(F)Z9,10Series Power Transformer
1.Load-ratio voltage regulation, high reliability, advanced level of performances, reasonable economical indicators. 2.The winding has novel structure and its oil passage is reasonable designed. Its newly designed insulation structure helps enhance its mechanical strength and the short circuit withstanding ability Please contact us! Email:
liujing@mec.com.cn
Description
Skype:liujingmec
liujing@mec.com.cn
Amount of local discharge :the apparent discharge amount under 1.5 times of rated voltage is less than 80PC;
Noise: products of 63MVA and below is lower than of IEC standard;
Power loss: no-load loss is 30% lower than that of IEC standard;
Reliability: all in-service products have no damages or oil leakage occurred;
Short circuit withstanding: model SFZ11-50000/132 smoothly passed the short-circuit withstanding test of the national transformer quality supervision and inspection center and also passed Holland “KENA” quality control system.
Main Technical Parameters for 110kv level S(F)Z9,10Series for
three-phase two winding on-load-tap-changing Power transformer
Rated
Power
(kVA)
|
High
Voltage
(kVA)
|
H.V.Tap
Range
|
Low
Voltage
(kVA)
|
Connection
Symbol
|
Short-Circuit
Impedance
(%)
|
No-Load
Loss
(kW)
|
On-Load
Loss
(kW)
|
No-Load
Current
(%)
|
Weight
(T)
|
Overall
dimension
|
|
9
|
10
|
9
|
10
|
|
Untanking weight
|
Total
|
L
|
W
|
H
|
6300
|
110
121
(132)
|
±8×1.25%
(± 9×1.67%)
|
6.3
6.6
10.5
11
(20)
(34.5)
|
YNd11
|
10.5
|
10.4
|
9.3
|
37
|
34.9
|
0.69
|
19.8
|
23.9
|
5450
|
4710
|
4320
|
8000
|
12.4
|
11.1
|
45
|
42.5
|
0.69
|
22.3
|
26.8
|
5570
|
4760
|
4470
|
10000
|
14.9
|
13.4
|
53
|
51.2
|
0.82
|
25
|
31.4
|
5950
|
4860
|
4580
|
12500
|
17.3
|
15.5
|
63
|
29.5
|
0.82
|
29.4
|
35.6
|
6010
|
4750
|
4690
|
16000
|
20.9
|
18.7
|
77
|
73.1
|
0.76
|
31.8
|
39.7
|
6340
|
4880
|
4830
|
20000
|
24.7
|
22.1
|
93
|
88.4
|
0.76
|
36.9
|
45
|
6420
|
5120
|
4840
|
25000
|
28.8
|
25.8
|
110
|
105
|
0.69
|
39.1
|
49.9
|
6550
|
5340
|
5020
|
31500
|
34.8
|
31.1
|
133
|
126
|
0.69
|
44.7
|
56.6
|
6600
|
5380
|
5100
|
40000
|
41.7
|
37.3
|
156
|
148
|
0.63
|
50.7
|
65.6
|
6720
|
5430
|
5300
|
50000
|
49.4
|
44.1
|
194
|
184
|
0.63
|
59
|
75.1
|
6880
|
5520
|
5340
|
63000
|
58.7
|
52.5
|
234
|
221
|
0.57
|
67
|
87.1
|
6980
|
5540
|
5630
|
Main Technical Parameters for 110kv level S(F)Z9,10 Series for
three-phase three winding on-load-tap-changing Power transformer
Rated
Power
(kVA)
|
High
Voltage
(kVA)
|
H.V.Tap
Range
|
Low
Voltage
(kVA)
|
Middle
Voltage
(kVA)
|
Connection
Symbol
|
Short-Circuit
Impedance
(%)
|
No-Load
Loss
(kW)
|
On-Load
Loss
(kW)
|
No-Load
Current
(%)
|
Weight
(T)
|
Overall
dimension
|
|
9
|
10
|
9
|
10
|
|
Total
|
L
|
W
|
H
|
6300
|
110
121
(132)
|
±2×2.5%
|
6.3
6.6
10.5
11
|
35
37
38.5
|
Ynyn0d11
|
10.5
17~18
6.5
|
12.4
|
11.1
|
47.7
|
45.1
|
0.84
|
23.9
|
6980
|
4220
|
4680
|
8000
|
14.9
|
13.4
|
56.7
|
53.6
|
0.84
|
26.8
|
7080
|
4580
|
4890
|
10000
|
17.6
|
15.8
|
66.6
|
62.9
|
0.79
|
31.4
|
7160
|
4580
|
5100
|
12500
|
20.2
|
18.1
|
78.3
|
74
|
0.79
|
35.6
|
7300
|
4800
|
5150
|
16000
|
25
|
22.4
|
95.4
|
90.1
|
0.74
|
39.7
|
7400
|
4900
|
5300
|
20000
|
29.6
|
26.5
|
112.5
|
106.3
|
0.74
|
45
|
7450
|
5000
|
5500
|
25000
|
34.9
|
31.2
|
133.2
|
125.8
|
0.69
|
49.9
|
7500
|
5160
|
5520
|
31500
|
41.6
|
37.2
|
157.5
|
148.8
|
0.69
|
56.6
|
7550
|
5200
|
5580
|
40000
|
49.7
|
44.5
|
189
|
178.5
|
0.64
|
65.6
|
7700
|
5250
|
5700
|
50000
|
48.5
|
52.6
|
225
|
212.5
|
0.64
|
75.1
|
7750
|
5400
|
5800
|
63000
|
69.9
|
62.6
|
270
|
255
|
0.59
|
87.1
|
7850
|
5450
|
5850
|