39-51KV Series Ploymer Housed High Voltage Surge Arrester

The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance.

Description

  • Model NO.: YH10W5-51/134
  • Structure: Zinc Oxide Arrester
  • Application: Substation
  • Operation Voltage: High Voltage
  • Material: ZnO
  • Brand: Yongde
  • Arc-Extinguishing Medium: Air
  • Creepage Distance: 2046mm
  • Specification: IEC 60099-4
  • HS Code: 85354000
  • Type: Power Source Arrester
  • Installation: Parallel Arrester
  • Size: Meidum
  • Shape: Cuboid
  • Certification: ISO9001
  • Breaking Capacity: High Voltage Circuit Breakers
  • Housing: Polymer
  • Trademark: YongDe
  • Origin: China

39-51 KV Product's Characteristics:
The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance
Simple in structure, small in size and light in weight
Polymer Housed with flexible silicone rubber, explosion-proof
ZnO varistor as the core component is large in flow capacity which is much higher than that of the national standard GB11032 and ANSI 62.22, and with high reliability.
With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
Products with detachment device can provide signals for quitting operation when failure occurs, avoiding arrester explosion, and it is maintenance-free.
Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.

Type

Maximum System Voltage(kV)

Rated Voltage(kV)

Continuous Operating Voltage(kV)

  MRV under 1/5 μ s Steep Discharge Current(kV)

MRV under 8/20 μ s Lightning  Discharge Current(kV) 

MRV under 30/60 μ s Operating  Discharge Current  (kV)

Line discharge class

Long duration impulse current at 2mS(A)

4/10 μ s High Current Impulse(kA)

Outside insulation standard(at IEC or ANSI) (kV)

IEC

ANSI

5kA

10kA

5kA

10kA

0.5kA

1kA

2kA

Lightning impulse withstand voltage kV

Power frequency withstand voltage (kV)

Y5W, Y10W-39

 
 
 
 
 
 
 
 
52
 

 
 
 
 
 
 
 
 
48.3

39

31.2

108

119

100

109

/

/

/

1

300

65

250

95

120/100

106

115

98

105

80.5

83

86.3

1

400

100

Y5W, Y10W-42

42

33.6

118

129.5

109

119

/

/

/

1

300

65

250

95

120/100

114.5

124

106

114

87

90

93.3

1

400

100

Y5W, Y10W-45

45

36

126

138

116

126.5

/

/

/

1

300

65

250

95

120/100

123.5

133

113

122

92.6

95.6

99.5

1

400

100

Y5W, Y10W-48

48

38.4

131

141

120

129.5

/

/

/

1

400

100

250

95

120/100

125.6

138.8

115.3

127.3

98.5

102

106

2

600

100

Y5W, Y10W-51

51

40.8

139.5

151.5

128

139

/

/

/

1

400

100

250

95

120/100

136

149

125

136.7

107

111

115

2

600

100

 