Remove Now
Cancle

72.5-252KV SF6 circuit breaker

LW35-72.5/126/145/252 SF6 circuit breaker is designed with self-energizing theory that the arc generated in the interrupter is distinguished at a specified time with a part of energy from the arc itself.

Description

Skype: liujingmec

liujing@mec.com.cn

LW35-72.5/126/145/252 SF6 circuit breaker is designed with self-energizing theory that the arc generated in the interrupter is distinguished at a specified time with a part of energy from the arc itself.

The circuit breaker is designed and manufactured in good accordance with IEC standards.

LW35-72.5/126/145 circuit breaker is either three-phase gang operation with a spring mechanism or single-phase operation with three spring mechanisms.

LW35-252 series circuit breaker is equipped with three spring mechanisms to realize single-phase operation or three-phase electrical gang operation.

1. Simple structure, high rated parameter

2. Spring mechanism, compactness

3. Easy installation, low noise, high reliability

4. Double sealing system is adopted to guarantee minimum SF6 annual leakage

5. Mechanical and electrical anti-pumping function.

6. Reasonable design, compact structure, no oil-leakage, maintenance-free, 10000 times mechanical endurance.

 

Item

Unit

LW35-72.5

LW35-126

LW35-145

LW35-252

Rated voltage

KV

72.5

126

145

252

Rated current

A

3150

4000

Rated frequency

Hz

50

Rated short circuit breaking current

kA

40

50

Rated short time withstand current (3s)

kA

40

50

Short line fault breaking current

kA

30/36

45/37.5

Rated peak withstand current

kA

100

125

Rated out-of-phase breaking current

kA

10

12.5

Rated line charging breaking current

A

10

31.5

50

160

Rated SF6 gas pressure (at 20℃)

Mpa

0.4

0.5

0.6

Main loop resistance

μΩ

≤40

≤45

≤60

Operation sequence

 

O-0.3s-CO-180s-CO or O-0.3s-CO-15s-CO

Mechanical endurance

Times

10000

SF6 gas leakage(rate per year)

%

≤1%

Moisture content (V/V)

PPm

150

Creepage

 

Across the open contacts

mm

2300

3950

3950

9400

To earth

mm

2300

3950

3950

7320

 

LW10B column type SF6 circuit breaker including 252kV, 363kV and 550kV products, are used for making and breaking normal current, fault current and changing over of circuit, so as to realize the control and protection of power system. Please contact us! Email: liujing@mec.com.cn

Year Established:

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: