Electrical Switch Power Distribution Cabinet Blokset Series Low Voltage Switchgear
Application Range: Substation, Building;
Trademark: Tianan Electric;
Origin: Xiangshan Zhejiang P. R China.
Description
- Model NO.: Blokset
- Shell Material: Steel Plate
- Structure: Cabinet, Protection
- Altitude: up to 3, 000m Above Sea Level
- Special Conditions: Depends on The Customer
- Busbar: 3-Phase and 4-Wire
- Typical Products: Low Voltage Switchgear
- Warranty: 10 Years
- Form: All- packaged Type
- Shell Protection Grade: IP56
- Application Range: Substation, Building
- Trademark: Tianan Electric
- Origin: Xiangshan Zhejiang P. R China
- Certification: VDE, CCC, ISO9001:2000, IEC62271:200
- Voltage Level: Low Voltage
- Rated Insulation Voltage: 660( 1000)V
- Environment: Outdoor
- Rated Voltage of Main Circuit( V): AC 380( 400, 660)
- Test Equipment: IEC Standard
- Frequency: 50
- Type: Distribution Metering Box
- Size: 3 Uint
- Operation Voltage: 10-24kv
- Brand: Tianan
- Specification: IEC60076-1, IEC60076-2, IEC60076-5
- HS Code: 8537209000
|
General >>A system for all your applications requiring a high level of dependability: ~~ Electrical distribution and motor control. ~~ A modular structure. ~~ For low-voltage switchboards, designed to meet local standards, practices and requirements. A multi-function range >>Type D: Distribution switchboards up to 6300 A >>Type DC: Power factor correction column >>Type Mf: Fixed-type motor-control centres up to 6300 A >>Type Mw: Withdrawable-type motor-control centres up to 6300 A >>Type Ms: Variable-speed drives and starters column >>Type C: Cubicles up to 630 A. A modular system >>Standardized components. >>Fast manufacturing. >>Easy modifications. Functional design 1)Rationalized dimensions and layout inside the switchboard. 2)Reduced footprint. 3)Easy power and auxiliary connections . 4)Easy installation upgrading at a controlled cost. 5)An intelligent system, ready to integrate devices containing advanced protection and communication functions for electrical distribution and motor control. Compliance to standards >>Compliance with international standards: IEC 60439-1 / VDE 0660 part 500. >>DIN 41-488 / BS 5486 / EN 60 439-1. >>Seismic withstand: Uniform Building code, California Building code. Electrical Characteristics >>Rated insulation voltage: 1000 VAC >>Rated operational voltage: 690 VAC >>Rated impulse withstand voltage: 12 KV >>Overvoltage category: IV >>Degree of pollution: 3 >>Frequency: 400 Hz, up to 400 Hz Main busbars rated current 1. Main busbars Single busbars Double busbars 2. Rated current up to 4000 A up to 6300 A 3. Rated peak withstand current 63, 105 187 kA 220 kA 4. Rated short-time current 30, 50 85 kA r ms / 1 s 100 kA r ms / 1 s Surface Protection >>External surface protection Epoxy powder polymerized at high temperature. Standard colors >>RAL 9002 (grayish white) / RAL 7016 (graphite grey). Specifications
|
Item
|
Data
|
|
rated voltage
|
380-660V
|
|
ratd voltage impacte indurance
|
8KV
|
|
rated frequency
|
50/60hz
|
|
grounding system
|
TT,IT, TN-S,TN-C-S
|
|
ratd voltage of auxiliary circuit
|
AC380,220v/ DC220v
|
|
maximum coil in and out broken circuit
|
4000A
|
|
pollution degree
|
3
|
|
rated current
|
4000A
|
|
horizontal busbar rated current
|
4000A
|
|
vertical busbar rated current
|
2000A,1000A
|
|
horizontal busbar ratd shorttime withstand current
|
50/80KA
|
|
horizontal busbar rated peak value withstand current
|
105/176KA
|
|
vertical busbar rated short time withstand current
|
50KA
|
|
vertical busbar rated peak value withstand current
|
105KA
|
|