Gcs Gck Ggd0 Electrical Switch Power Distribution Cabinet Switchgear
Operation Voltage: 10-24kv;
Brand: Tianan;
Specification: IEC60076-1, IEC60076-2, IEC60076-5;
HS Code: 8537209000.
Description
- Model NO.: GGD
- Shell Material: Steel Plate
- Structure: Cabinet, Protection
- Altitude: up to 3, 000m Above Sea Level
- Special Conditions: Depends on The Customer
- Busbar: 3-Phase and 4-Wire
- Typical Products: Ggd
- Warranty: 10 Years
- Form: All- packaged Type
- Shell Protection Grade: IP56
- Application Range: Substation, Building
- Trademark: Tianan Electric
- Origin: Xiangshan Zhejiang P. R China
- Certification: VDE, CCC, ISO9001:2000, IEC62271:200
- Voltage Level: Low Voltage
- Rated Insulation Voltage: 660( 1000)V
- Environment: Outdoor
- Rated Voltage of Main Circuit( V): AC 380( 400, 660)
- Test Equipment: IEC Standard
- Frequency: 50( 60)
- Type: Distribution Metering Box
- Size: 3 Uint
- Operation Voltage: 10-24kv
- Brand: Tianan
- Specification: IEC60076-1, IEC60076-2, IEC60076-5
- HS Code: 8537209000
|
General >>A system for all your applications requiring a high level of dependability: ~~ Electrical distribution and motor control. ~~ A modular structure. ~~ For low-voltage switchboards, designed to meet local standards, practices and requirements. A multi-function range >>Type D: Distribution switchboards up to 6300 A >>Type DC: Power factor correction column >>Type Mf: Fixed-type motor-control centres up to 6300 A >>Type Mw: Withdrawable-type motor-control centres up to 6300 A >>Type Ms: Variable-speed drives and starters column >>Type C: Cubicles up to 630 A. A modular system >>Standardized components. >>Fast manufacturing. >>Easy modifications. Functional design 1)Rationalized dimensions and layout inside the switchboard. 2)Reduced footprint. 3)Easy power and auxiliary connections . 4)Easy installation upgrading at a controlled cost. 5)An intelligent system, ready to integrate devices containing advanced protection and communication functions for electrical distribution and motor control. Compliance to standards >>Compliance with international standards: IEC 60439-1 / VDE 0660 part 500. >>DIN 41-488 / BS 5486 / EN 60 439-1. >>Seismic withstand: Uniform Building code, California Building code. Electrical Characteristics >>Rated insulation voltage: 1000 VAC >>Rated operational voltage: 690 VAC >>Rated impulse withstand voltage: 12 KV >>Overvoltage category: IV >>Degree of pollution: 3 >>Frequency: 400 Hz, up to 400 Hz Main busbars rated current 1. Main busbars Single busbars Double busbars 2. Rated current up to 4000 A up to 6300 A 3. Rated peak withstand current 63, 105 187 kA 220 kA 4. Rated short-time current 30, 50 85 kA r ms / 1 s 100 kA r ms / 1 s Surface Protection >>External surface protection Epoxy powder polymerized at high temperature. Standard colors >>RAL 9002 (grayish white) / RAL 7016 (graphite grey).
Specifications
|
Rated voltage of main circuit( V)
|
AC 380( 400, 660)
|
|
Rated voltage of auxiliary circuit( V)
|
AC 220 380( 400) DC 110, 220
|
|
Rated frequency( Hz)
|
50( 60)
|
|
Rated insulation voltage( V)
|
660( 1000)
|
|
Rated current ( A)
|
Horizontal busbar
|
< =4000
|
|
Vertical busbar
|
1000
|
|
Rated short time withstand current of busbar( kA/1s)
|
50, 80
|
|
Rated peak withstand current of busbar( kA/0.1s)
|
105, 176
|
|
Power frequency testing voltage (V/1min)
|
Main circuit
|
2500
|
|
Auxiliary circuit
|
1760
|
|
Busbar
|
3-phase and 4-wire
|
A. B. C. PEN
|
|
3-phase and 5-wire
|
A. B. C. PE. N
|
|
Protection degree
|
IP3L0. IP4L0
|
|
Dimensions
|
2200x (600 800 1000)x600(800 1000)
|
|