Remove Now
Cancle

IEC6 1378 JB/T 8636-1997 Oil immersed Rectifier Transformer

Rectifier transformers are combined with a diode or thyristor rectifier. 1,Low loss 2,low partial discharge 3,Enviromental Protection 4,Loss impedance

Description

  • Place of Origin: Jiangsu, China (Mainland)
  • Brand Name: TIANWEI WUZHOU
  • Model Number: ZS ZH ZQ ZHS
  • Usage: Rectifier
  • Phase: Three
  • Coil Structure: Toroidal
  • Coil Number: 3
  • Color: grey
  • Type: Rectifier
  • Voltage: 10kV-220kV
  • winding material: copper
  • equipment: power transmission equipment
  • standard: IEC6 1378 JB/T 8636-1997

 

Rectifier transformers are combined with a diode or thyristor rectifier. The applications range from very large aluminum electrolysis to various small and medium size operations. The transformers may have a built-in or separate voltage regulation unit for direct output regulation of diode rectifiers , and correspondingly a power factor improvement with a thyristor rectifiers Rectifier Transformer
1) Matching with intermediate frequency induction furnace
2) ISO9001,ISO14001,CE

 

Rectifier transformers are combined with a diode or thyristor rectifier. The applications range from very large aluminum electrolysis to various small and medium size operations. The transformers may have a built-in or separate voltage regulation unit for direct output regulation of diode rectifiers , and correspondingly a power factor improvement with a thyristor rectifiers

 

 

Features:

 

1)    Low loss

2)    Low noise

3)    High efficiency

4)    Low partial discharge

5)    Strong mechanical strength and short-circuit withstand ability .

6)    Operation reliability

7)    Easy maintenance 

8)    Pretty outline and compact structure

9)    100% guaranteed no leakage

 

 

Brief specification

 

1)    Voltage class: 6~110 KV

2)    Capacity : 630 KVA to 120,000 KVA

3)    Short-circuit impedance : 4.5~21%

Losses: No-load losses is fully comply with IEC standard requirements

 

 

Application:

 

1)    Aluminum smelting

2)    Magnesium smelting

3)    Copper smelting

4)    Zinc smelting

5)    The largest installations are those for aluminum electrolysis with several transformer/rectifier units in parallel operation to achieve the required DC current, in all cases the rectifier can be with diodes or thyristors

 

 

 

FEATURES:

 

1.The rectifier transformer's load is non-linear impedance, and valve side windings of rectifier transformer would get the currents which contain fundamental and other high-order harmonic superposition. And line side also gets corresponding non-sinusoidal currents connected by rectifier circuit coupling method.

 

The valve side of rectifier transformer has a variety of special coupling method, such as: dual-back-star with inter phase reactor, three-phase bridge, star-delta parallel, six-phase bridge by inter phase reactor.

 

3,These high-power rectifier transformer is needed to use star-delta winding phase displacement, phase-shift windings by phase displacement, autotransformer phase displacement, to improve the number of pulse of rectifier equipment.

 

4,According to the user’s process requirements, the rectifier transformer line side voltage is required (such as 220kV) straight down to a very low valve side voltage (such as 1kV). The valve side voltage of rectifier transformer is required within a wide range of on-load tap from 5% - 105%.

 

5.Self-saturable reactor can be used to change over and stabilize voltage in order to smooth rectify voltage. And some use silicon control to regulate voltage.

 

6.Valve side current of high-power rectifier equipment is very large, reaching 100kA and even greater,it’s required the technology of reverse-phase parallel.

 

7.With the wide application of AC frequency control technology, newly developed three-crack drive rectifier transformer came into being. And the lower voltage valve side of this transformer cracked into three independent branches, which can be made to supply for three different load power, which achieve “ multi functional ” effect, reducing loss and saving area.8,Power and magnetic shielding technology and so on are used.

 

Main technical parameter

 

Type

Rated power
(kVA)

Rated Voltage(V)

Connection
Symbol

Weight(kg)

Overall Dimension
L×W×H
(mm)

Gauge
(mm)

Line side

Valve side

Active part

Oil

Total

ZSSP-800/10

800

10000

400

Dyn11

1580

660

3240

2160×1625×1855

820

ZSSP-2000/35

2000

35000

400

Yyn0

3320

1280

5735

2600×1260×2740

1070

ZSSP-4000/35

4000

35000

950

Dd0y11

5410

2040

9540

2570×1745×2720

1475

ZSSP-6300/35

6300

35000

1000

D(±7.5º)dyn

8600

4860

18260

3340×1875×2720

1475

ZSSP-7000/35

7000

35000

950

Dd0y11

8570

3390

14700

3185×985×3475

1475

ZSSP-8000/22

8000

22000

950

Dd0y11

8640

3340

14710

3210×1905×3375

1475

ZSSP-8000/35

8000

35000

950

Dd0y11

9170

3590

15520

3340×1870×3490

1475

ZSSP-9000/35

9000

35000

950

Dd0y11

9920

4070

15740

3240×1915×3720

1475

ZSSP-10000/35

10000

35000

1000

D(±7.5º)dyn

11090

4400

18850

3410×1915×3845

1475

 

 

 IEC6 1378 JB/T 8636-1997 Oil immersed Rectifier Transformer

 

 IEC6 1378 JB/T 8636-1997 Oil immersed Rectifier Transformer

Year Established:2000

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: No. 5, Xinjing East Road, South Of Economic Development Zone, Zhangjiagang, Jiangsu, China (Mainland)