Do you want to remove "electric slickline equipment" from your favorites?
Remove Now
Cancle
Li-ion battery pack 12v 10ah emergency lighting
More than 500 cycle life; High capacity; No pollution,low-self discharge
Parameter
Brand Name: : TianHong
Model Number: : TH-12V5-10AH
Composed Type: : 3s1p
Type: : Li-Ion
Components: : Li-polymer
Size: : 76*30*139mm
Voltage: : 12V
Weight: : 0.4 kg
Nominal Capacity: : 5Ah
Application: : Emergency Light
Certificates: : CE,RoHS,UN38.3,etc
Warranty: : 24 Months
Place of Origin: : Zhejiang, China
Description
General
This specification defines the requirements for a Lithium Ion polymer rechargeable battery product by TH. If any item is without a specific temperature, it means 25±3°C condition.
Product Type and Model
Type: Lithium Ion polymer power battery
Model: THP-12V/5Ah
Performance
|
S/N
|
Item
|
li-ion battery pack 12v 10ah
|
|
1
|
Capacity
|
5Ah
|
|
2
|
Working voltage
|
12V
|
|
3
|
Impedance
|
≤50mΩ
|
|
4
|
Charge limited voltage
|
12.6V
|
|
5
|
Discharge limited voltage
|
9V
|
|
6
|
Charge limited current
|
0.02C
|
|
7
|
Standard charge
|
0.2C(1A) CC to limited voltage ,then CV to limited current.
|
|
8
|
Standard discharge
|
0.5C(2.5A) DC to limited voltage
|
|
9
|
Max charge current
|
0.5C(2.5A)
|
|
10
|
Max discharge current
|
1C(5A)
|
|
3.11
|
Operation temperature
|
Charge: 0 ~ 45°C
|
|
Discharge: – 20 ~ 55°C
|
|
Storage temperature scope
|
-20 ~55°C≤1month; -20 ~ 45°C≤3 months; -10 ~ 30°C≤12months
|
|
12
|
Operation and storage humidity
|
45~75% RH
|
|
13
|
Weight
|
Approx 0.6kg
|
|
14
|
Size(mm)
|
T*W*L: 25*74*150 (MAX)
|
Safety Characteristics Test
|
S/N
|
Items
|
Criteria
|
Test Instructions
|
|
1
|
Overcharge
|
No fire, no explore,cell temperature no above 150°C.
|
After fully charged at constant current of 0.5C2.5A,
batteries are charged continually to 14.4V or for 1.5h at
constant current of 1A, then 14.4V CV for 7h.
|
|
2
|
Over discharge
|
No fire, no explore,cell temperature no above 150°C.
|
Discharge to limited voltage with 0.5C(2.5A) at 20±2 °C.
Then discharge to 0V with 0.2C(1A).
|
|
3
|
Short-circuit test
|
No fire, no explore,cell temperature no above 150°C.
|
Batteries are short-circuited by connecting the positive
and negative terminals with a resistance load of ≤50mΩ
until batteries’ temperature come back to no above RT 10°C.
|
|
4
|
Heating test
|
No fire, no explore,cell temperature no above 200°C.
|
Batteries are heated in a circulating
air oven at a rate of 5°C±2°C per minute to 85°C,
and then placed for 120 minutes at 85°C.
|
To insure safety, PCB &BMS Parameter should meet requirement as below.
Protective performance
|
S/N
|
Unite
|
Items
|
Requirement
|
|
1
|
Adapter
|
Charge limited voltage
|
12.6V
|
|
2
|
BMS
(For reference)
|
Over-Charge Protective Voltage
|
12.75V
|
|
3
|
Over-charge return voltage
|
12.45V
|
|
4
|
Discharge limited voltage
|
9V
|
|
5
|
Over-Discharge Protective Voltage
|
8.4V
|
|
6
|
Protective Current
|
----
|
Li-ion battery pack 12v 10ah emergency lighting
Zhejiang Tianhong Energy Technology Co., Ltd.
Year Established:2003
Business Type:Manufacturer
Management Certifiation: ISO9001:2008
Operational Address: New Industry Zone, Zhicheng Town, Changxing County, Huzhou, Zhejiang, China
Verified Supplier
Credit Check
More from this Supplier