Remove Now
Cancle

Rum Metal-Clad MID-Mount AC Electrical Switch Power Distribution Cabinet Switchgear

Mainly applicable in the power plant, substation, mineral enterprise to receive and Distribute power with the functions of controlling, protecting and monitoring. It also can be used in places where the frequently operations are in need.

Description

  • Model NO.: KYN28A
  • Shell Material: Steel Plate
  • Current: AC
  • Altitude: up to 3, 000m Above Sea Level
  • Special Conditions: Depends on The Customer
  • Busbar: 3-Phase and 4-Wire
  • Typical Products: Kyn28A
  • Warranty: 10 Years
  • Form: All- packaged Type
  • Shell Protection Grade: IP56
  • Application Range: Substation, Building
  • Trademark: Tianan Electric
  • Origin: Xiangshan Zhejiang P. R China
  • Certification: VDE, CCC, ISO9001:2000, IEC62271:200
  • Structure: Cabinet, Protection
  • Rated Insulation Voltage: 660( 1000)V
  • Environment: Outdoor
  • Rated Voltage of Main Circuit( V): AC 380( 400, 660)
  • Test Equipment: IEC Standard
  • Frequency: 50
  • Type: Distribution Metering Box
  • Size: 3 Uint
  • Operation Voltage: 10-24kv
  • Brand: Tianan
  • Specification: IEC60076-1, IEC60076-2, IEC60076-5
  • HS Code: 8537209000

General
>>Ratings: system voltage 3.6kV, 7.2KV, 12KV, 24KV,rated current up to 4000A, 
          AC three phase 50/60HZ.
>>Application: mainly applicable in the power plant, substation, mineral enterprise to receive and 
             Distribute power with the functions of controlling, protecting and monitoring. It also can be  
             used in places where the frequently operations are in need.
>>Standard: IEC62271-200.


Working Conditions
1. Ambient air temperature: -15°C~+40°C.
2. Altitude: ≤1000m.
3. Relative humidity : Daily average≤95%, daily averange of vapour pressure≤2.2kpa.
4. Earthquake intensity: ≤magnitude 8.
5. Applicable in the places without corrosive and flammable gas and water vapor.
6. Used in place without frequently intense vibrant.
  Note: Customized products are available.

Specifications

Item

Unit

Data

 

Rated voltage

kv

3.6, 7.2, 12,24KV

 

Rated frequency

hz

50

 

Rated current of circuit breaker

A

630, 1250, 1600, 2000, 2500, 3150, 4000

 

Rated current of switchgear

A

630, 1250, 1600, 2000, 2500, 3150, 4000

 

Rated short-time withstands current(4s)

ka

16, 20, 25, 31.5, 40, 50

 

Rated peak withstands current (peak value)

ka

40, 50, 63, 80, 100, 25

 

Rated short-circuit breaking current

ka

16, 20, 25, 31.5, 40, 50

 

rated short-circuit making current (peak value)

ka

40, 50, 63, 80, 100, 25

 

Rated insulation level

1min power frequency withstands voltage

pole to pole, pole to ground

kv

24, 32, 42

 

fracture to fracture

kv

24, 32, 48

 

lightning withstands voltage(peak)

pole to pole, pole to ground

kv

40, 60, 75

 

fracture to fracture

kv

46, 70, 85

 

Protection degree

Enclosure is IP4X. IP2X when CPT and CB door are open

 

Note: 
1. The short-circuit capacity of current transformer is considered separately.                                                                                                          
2. Details of the parameters of ZN 63A-12 as per reference company' s sample.

 
 
           

 

 

 

Rum Metal-Clad MID-Mount AC Electrical Switch Power Distribution Cabinet Switchgear

Year Established:

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: No. 1118, Tianan Road, Xiangshan, Ningbo, Zhejiang, China