Remove Now
Cancle

SafeClad-624e non-extensible sf6 gas insulated LV switchgear

Rated current: 630A/1250A; Standard: IEC /ANSI Standard; Certificate: ISO9001; Usage: Electricity Transmission Project?;

Description

  • Place of Origin: Hunan, China (Mainland)
  • Brand Name: HXXN
  • Model Number: SafeClad-624e
  • Type: Gas-insulated
  • Rated Voltage: 3.6kV,7.2kV,11kV,12Kv,15kV,22kV,24kV,33kV,36kV,40.5kV
  • Rated frequency: 50/60Hz
  • Rated current: 630A/1250A
  • Standard: IEC /ANSI Standard
  • Certificate: ISO9001
  • Usage: Electricity Transmission Project

 

Professional Medium voltage and Low voltage switchgear manufacturer in China

Operating environment: 

1)Ambient temperature:-10°C-+40°C;  

2)Altitude: high voltage ≤1000Meter, low voltage ≤2500Meter (technical department will design specially if exceeds);

3)Relative humidity:≤85%

4)Seismic intensity:≤ magnitude 8;

5Apply to the places have no fire,no explosion danger, no serious pollution,no chemical corrosion and no violent vibration.

  C-GIS sf6 630a switchgear

 

Executive standard:

GB7251         Low voltage complete set switchgear and control device

GB3906-2006    3.6kV~40.5kV AC metal enclosed switchgear and control device

  C-GIS sf6 630a switchgear

 

Technical parameter:

 

35KV high voltage switchgear technical parameter:

C-GIS sf6 630a switchgear 

 

Parameter

Rated voltage

kV

40.5~33KV

Rated short time power frequency withstand voltage(1min)(1min)

kV

95

Rated lighting impulse withstand voltage

kV

185

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500

Rated short circuit breaking current

kA

25

31.5

Rated peak value withstand current

kA

63

80

Rated control power

V

AC 110/220,DC 110/220

Dimension

KYN61-40.5

mm

1400*2800*2600

(width* depth* height)

 

 

 

 

 

 

24KV high voltage switchgear technical parameter:

C-GIS sf6 630a switchgear  

 

Parameter

Rated voltage

kV

24~15KV

Rated short time power frequency withstand voltage(1min)

kV

65

Rated lighting impulse withstand voltage

kV

125

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500

Rated short circuit breaking current

kA

25

31.5

Rated peak value withstand current

kA

63

80

Rated control power

V

AC 110/220,DC 110/220

Dimension

KYN28A-24

mm

1000*1800*2450(width*depth*height)

 

 

 

 

 

 

12KV high voltage switchgear technical parameter:

C-GIS sf6 630a switchgear  

 

Parameter

Rated voltage

kV

3.6

7.2

12

Rated short time power frequency withstand voltage(1min)

kV

24

32

42

Rated lighting impulse withstand voltage

kV

40

60

75

Rated frequency

Hz

50

Rated current

A

630,1250,1600,2000,2500,3150,4000

Rated short circuit breaking current

kA

20

25

31.5

40

50

Rated peak value withstand current

kA

50

63

80

100

125

Rated control power

V

AC 110/220,DC 110/220

Dimension

(width*depth*height)

KYN28A-12

mm

(800/1000)*1500*2300

XGN2-12

mm

1100*1200*2650

HXGN-12

mm

(375/500)*900*1850

 

 

 

 

 

 

 

 

 

 

 

0.4KV low voltage switchgear technical parameter:

 

 

Parameter

Rated voltage

V

               400

690

Rated insulation voltage

V

690

1140

Rated impact withstand voltage

V

6000

10000

Rated working short circuit breaking ability

kA

18~100

10~75

Rated utmost short circuit breaking ability

kA

25~120

20~85

Rated frequency

Hz

50/60

Rated current

A

400,500,630,800,1000,1250,1600,2000,2500,3150,4000,5000,6300

Rated control power

V

AC 110/220/380,DC 110/220

Dimension

(Unit:mm)

MNS/GCS/GGD

width

400,600,800,1000,1200

depth

600,800,1000

height

220

 

 

 SafeClad-624e non-extensible sf6 gas insulated LV switchgear

Year Established:2015

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: Room 803, Yanggujinyuan, No. 39, Luhu Road, High-Tech Development Zone, Changsha, Hunan, China (Mainland)