Remove Now
Cancle

iSafering 12kv 17.5kv 24kv Sf6 Gas Insulated Ring Main Unit Switchgear

iSafeRing is a SF6 insulated ring main unit for the secondary distribution network. iSafeRing can be supplied in 10 different configurations suitable for most switching applications in 12/24/36 kV distribution networks. As an option, iSafeRing can be delivered as extendable ring main unit.

Description

  • Model NO.: iSafering
  • Structure: Protection
  • Form: All- packaged Type
  • Size: 2 Uint
  • Shell Material: Steel Plate
  • Brand: Unisun
  • Rated Frequency: 50Hz
  • Lightning Impulse Withstand Voltage: 95/95/125
  • Trademark: UNISUN
  • Specification: 12KV/24KV
  • HS Code: 85372090
  • Type: Power
  • Certification: ISO9001:2000, VDE, CCC
  • Operation Voltage: High Voltage
  • Application Range: High-rise Buildings
  • Shell Protection Grade: IP56
  • Rated Voltage: 12/ 17.5/ 24kv
  • Power Frequency Withstand Voltage: 28/38/50
  • Rated Normal Current: 630A
  • Transport Package: Wooden
  • Origin: China

 

iSafering SF6 insulated Ring Main Unit
Gas Insulated Ring Main Unit
iSafeRing is a SF6 insulated ring main unit for the secondary distribution network. iSafeRing can be supplied in 10 different configurations suitable for most switching applications in 12/24/36 kV distribution networks. As an option, iSafeRing can be delivered as extendable ring main unit.
Together, iSafeRing represent a complete solution for 12/24/36 kV secondary distribution networks.

C - Cable switch module

 F - Cable switch module

 V - Cable switch module

D - Direct cable connection module

 De - Direct cable connection module with earthing switch

 M - Metering module

Modularity and external busbar
All modules except the metering module and circuit-breaker module are only 325 mm wide.
Transformer protection
iSafering offers a choice between a switch fuse combination and circuit breaker with relay for transformer protection. The switch fuse combination offers optimal protection against short-circuits, while the circuit breaker with relay option offers better protection against low overcurrents. Circuit breaker with relay is always recommended for larger transformers.
Normal operation conditions
The rated characteristics of the switchgear are valid under the following ambient conditions:
minimum ambient temperature: - 25 °C
maximum ambient temperature: + 40 °C
For different temperature ranges, please contact your UNISUN sales representative.
Standards
iSafeRing/iSafePlus is tested according to following
IEC-standards:
IEC 62271-1/IEC 62271-100/IEC 62271-102/IEC 62271-103/IEC 62271-105/IEC 62271-200/IEC 60529

 

SafeRing

C-module

F-module

V-module

Switch disconnector

Earthing switch

Switch-fuse disconnector

Downstream earthing switch

Vacuum circuit-breaker

Earthing switch/ disconnector

Rated voltage

Kv

12/17,5/24

12/17,5/24

12/17,5/24

12/17,5/24

12/17,5/24

12/17,5/24

Rated frequency 5)

Hz

50/50/50

50/50/50

50/50/50

50/50/50

50/50/50

50/50/50

Power frequency withstand voltage

kV

28/38/50

28/38/50

28/38/50

28/38/50

28/38/50

28/38/50

Lightning impulse withstand voltage

kV

95/95/125

95/95/125

95/95/125

95/95/125

95/95/125

95/95/125

Rated normal current

A

630/630/630

 

2001)

 

200/200/200

 

Breaking capacities:

 

 

 

 

 

 

 

active load

A

630/630/630

 

 

 

 

 

closed loop

A

650/650/650

 

 

 

 

 

off load cable charging

A

140/140/140

 

 

 

 

 

off load transformer

A

 

 

20/20/20

 

 

 

earth-fault

A

205/160/160

 

 

 

 

 

earth-fault cable charging

A

117/91/91

 

 

 

 

 

short-circuit breaking current

kV

 

 

see2)

 

16/16/16

 

Making capacity

kV

52,5/40/40

52,5/40/40

see2)

12,5/12,5/12,5

40/40/40

40/40/40

Short time current 3 sec. 3)

kV

21/16/16

21/16/16

 

 

16/16/16

16/16/16

iSafering 12kv 17.5kv 24kv Sf6 Gas Insulated Ring Main Unit Switchgear

Year Established:

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: Economic Development Zone, Yueqing, Wenzhou, Zhejiang, China