Remove Now
Cancle

24kv-630A Hv Electric Vmd Fixed & Withdrawal Type Vacuum Circuit Breaker

The complete specification of VMD series vacuum circuit breaker can meet customers' different needs. It adopts the latest embedded poles and low-resistance vacuum interrupter and employs an accurate gear driving system in the place of tradidtional chain wheel driving system.

Description

  • Model NO.: VMD
  • Operation: Manual & Electric Type Breaker
  • Arc-extinguishing Medium: Vacuum
  • Structure: Vcb Breaker
  • Type: Circuit Breaker
  • Certification: ISO9001-2000
  • Rated Current: 630A Breaker
  • Rated Short-Time Withstand Current: 20/25/31.5A Breaker
  • Rated Short-Circuit Opening Current: 20/25/31.5ka Breaker
  • Trademark: Mingde Breaker
  • Specification: SGS, TUV
  • HS Code: 8535210000
  • Breaking Capacity: Middle& High Voltage Breaker
  • Speed: Normal Type Circuit Breaker
  • Installation: Fixed & Withdrawal Type Breaker
  • Poles Number: 3
  • Function: Overcurrent Protection
  • Rated Voltage: 24kv Breaker
  • Rated Frequency: 50Hz Breaker
  • Rated Withstand Current(Peak): 50/63/80ka Breaker
  • Mechanical Life: 30000times Breaker
  • Transport Package: Wooden Case Breaker
  • Origin: Cixi, Ningbo, Zhejiang Breaker

 

Product Overview

The complete specification of VMD series vacuum circuit breaker can meet customers' different needs. It adopts the latest embedded poles and low-resistance vacuum interrupter and employs an accurate gear driving system in the place of tradidtional chain wheel driving system. With main conductive circuit sealed in epoxy resin, the insulation performance will be more stable. VMD series circuit breaker passed Type Test Report according to GB and IEC standards and has been exported to 26 countries and regions in the world.

Main Parameters
 

NO

Item

Unit

Technical Data

1

Rated voltage

KV

24

2

Rated insulating level

Rated short time power frequency withstand voltage(1 min)

65

Rated lighting impulse withstand voltage(peak value)

125

3

Rated frequency

HZ

50

4

Rated current

A

630

630

1250

1250

1250

1600

 

 

2000

2500

5

Rated short circuit breaking current

KA

20

25

31.5

6

Rated short time withstand current

20

25

31.5

7

Rated peak withstand current

50

63

80

8

Rated short-circuit making current       (peak value)

50

63

80

9

4S Rated short-time withstand current

20

25

31.5

10

Rated peak value of current

50

63

80

11

Rated making surge current of capacitor bank

12.5(The frequency is less than 1000Hz)

12

Rated breaking current of single/symmetrical capacitor bank

630/400(The value should be 800/400 while the current is 40KA)

13

Mechanical life

Times

10000,30000,60000

14

Duration of rated short-circuit current

s

4

15

Power frequency withstand voltage of secondary circuit

V

2000

16

Rated operational voltage

Making coil

AC110/220  DC110/220

Breaking coil

AC110/220  DC110/220

Energy-storage motor

AC110/220  DC110/220

17

Making time(under Rated voltage)

ms

≤60

18

Breaking time(under Rated voltage)

≤45

19

Permitted abrasion thickness of moving and fixed contacts

mm

3

20

Energy storage time

S

<=15

21

Clearance

mm

131

22

Travel

41

23

Bounce time(making)

ms

<=2

24

Three pole making/breaking non-simultaneity

<=2

25

Average breaking speed

1.1~1.7

26

Average making speed

0.6~1.1

27

Contact pumping (breaking)

mm

≤3

28

Conductance circuit resistance

μΩ
 

Withdrawal Style

Rated current

≤45

630~1250A

≤35

1600~2000A

≤25

More than 2500A

29

Rated operating order

 

O-0.3s-CO-180s-CO

                 

 
Normal Operating Environment Condition

a) Normal operating environment condition
Highest temperature:                  +40ºC
Lowest temperature:                   -15ºC
b) Environment humidity
Daily mean relative humidity:        ≤95%
Monthly mean relative humidity:     ≤90%
Daily mean saturated vapor pressure:   ≤2.2×10-3 MPa
Monthly mean saturated vapor pressure:  ≤1.8×10-3 MPa
c) Altitude: below 1000m area;
d) Earthquake intensity: no more than 8 degree;
e) The product shall be away from weep, fire and explosion, chemical corrosion and 
strenuous vibration place.

Special Operating Condition

Please consult with manufacturer on manufacturing technology when operating environment is the climatic environment with high altitude, high humidity and great temperature change or other special environment condition

24kv-630A Hv Electric Vmd Fixed & Withdrawal Type Vacuum Circuit Breaker

Year Established:

Business Type:Manufacturer, Trading Company

Management Certifiation:

Operational Address: 12th Floor, No. 2 Building of Jinjia Business Square, 789 Tianzhu Road, Jiading District, Shanghai