ISO9001-2000 Zw20 12kV Mingde Outdoor Vacuum Circuit Breaker
Rated Power of The Motor: 40W Circuit Breaker;
Trademark: Mingde Circuit Breaker;
Specification: CE, ISO9001 Circuit Breaker;
HS Code: 8535210000;
Description
- Model NO.: 12kV Mingde Outdoor Circuit Breaker
- Operation: Electric & Manual Circuit Breaker
- Arc-extinguishing Medium: Vacuum
- Structure: High and Medium Voltage Circuit Breaker
- Type: Circuit Breaker
- Certification: ISO9001-2000, CE
- Rated Frequency: 50Hz Circuit Breaker
- Mechanical Life: 10000 Times Circuit Breaker
- Rated Short Circuit Breaking Times: 30 Times Circuit Breaker
- Transport Package: Wooden Case Packing Circuit Breaker
- Origin: Cixi, Ningbo. Zhejiang Circuit Breaker
- Breaking Capacity: Middle& High Voltage Circuit Breaker
- Speed: Normal Type Circuit Breaker
- Installation: Fixed
- Poles Number: 3
- Function: Overcurrent Protection
- Rated Current: 630A Circuit Breaker
- Rated Short-Circuit Making Current: 50ka Circuit Breaker
- Rated Power of The Motor: 40W Circuit Breaker
- Trademark: Mingde Circuit Breaker
- Specification: CE, ISO9001 Circuit Breaker
- HS Code: 8535210000
Main technical data of the circuit breaker ZW20
|
No.
|
Item
|
Unit
|
Numerical value
|
|
1
|
Rated voltage
|
kV
|
12
|
|
2
|
Rated current
|
A
|
630
|
|
3
|
Rated frequency
|
Hz
|
50
|
|
4
|
Rated short-circuit breaking current
|
kA
|
20
|
|
5
|
Rated peak withstand current
|
kA
|
50
|
|
6
|
Rated short-time withstand current
|
kA/S
|
20/4
|
|
7
|
Rated short-circuit making current (peak value)
|
kA
|
50
|
|
8
|
Rated operating sequence
|
|
O-0.3S-CO-180s-CO
|
|
9
|
Mechanical life
|
times
|
10000
|
|
10
|
Rated short-circuit breaking times
|
times
|
30
|
|
11
|
1 min frequency withstand
|
(wet) between poles, to earth/ between open contacts
|
kV
|
34
|
|
(dry) (wet) between poles, to earth/ between open contacts
|
kV
|
42
|
|
12
|
Rated lightning impulse withstand current (peak value) between poles, to earth/between open contacts
|
kV
|
85
|
|
13
|
Power frequency withstand voltage of secondary circuit (1 min)
|
V
|
2000
|
|
14
|
SF6 gas pressure
|
Mpa
|
0
|
Main technical features of the circuit breaker ZW20
|
No.
|
Item
|
Unit
|
Numerical value
|
|
1
|
Clearance
|
mm
|
9±1
|
|
2
|
Travel
|
mm
|
3~4
|
|
3
|
Opening speed
|
m/s
|
1.2±0.2
|
|
4
|
Closing speed
|
m/s
|
0.6±0.2
|
|
5
|
Bounce time(contacts closing)
|
m/s
|
≤2
|
|
6
|
Pole center distance
|
mm
|
135(inside)/280(outside)
|
|
7
|
Three pole opening/closing non-synchronism
|
ms
|
≤2
|
|
8
|
Each pole's conductance circuit resistance
|
μΩ
|
≤150
|
|
9
|
Closing time
|
ms
|
25~60
|
|
10
|
Opening time
|
ms
|
20~50
|
|
11
|
Rated power of the motor
|
W
|
40
|