- Place of Origin: Henan, China (Mainland)
- Brand Name: Runner
- Model Number: ZW32-12
- Type: High Voltage
- Poles Number: 3
- Product name: 12kv Electric circuit breaker with remote control device
- electrical circuit breaker type: spring and permanent magnet
- electric circuit breaker rated voltage: 12KV
- electric circuit breaker rated current: 630A 1250A
- electric circuit breaker frenquency: 50HZ
- circuit breaker opening speed: 1.2±0.2ms
- circuit breaker closing speed: 0.6±0.2ms
- electrical circuit breaker weight: 120kg
- outdoor circuit breaker altitude: less than 1000m
- circuit breaker working temperature: - 40℃-- 50℃
1. Insulation test: outdoor vacuum circuit breaker main electricity loop insulation is stable and reliable;
2. Mechanical property and environmental testing: mechanical property is stable and reliable;
3. Temperature rise test: Vacuum interrupter with ultra-low resistance, contacting resistance is low;
4. Testing for Turning on or off and opening or closing on rated short circuit :
5. High vacuum breaking ability is great, insulation recovery is fast, breaker finished short-circuit current test for 30 times;
6. Testing for short-time withstand current and peak withstand current:
7. Outdoor vacuum circuit breaker test for 4 seconds withstand current and short-time peak withstand current, power receiving ability on main loop is great;
8. Testing for life : 30000 times finished on State new standard M2 grade.
circuit breaker technical parameters:
|
No
|
Items
|
Unit
|
Number
|
|
1
|
Rated voltage
|
KV
|
12
|
|
2
|
Rated current
|
A
|
630 or 1250
|
|
3
|
Rated frequency
|
Hz
|
50
|
|
4
|
Power frequency resisting voltage(1min)
|
KV
|
42
|
|
5
|
Withstand current(peak) for thunder
|
KV
|
75
|
|
6
|
Rated short-circuit current for turning on or off
|
KA
|
16/20/25
|
|
7
|
Rated short-circuit current for opening or closing (peak number)
|
KA
|
50
|
|
8
|
Rated peak withstand current
|
KA
|
50
|
|
9
|
4s short-time withstand current
|
KA
|
20
|
|
10
|
Rated operation cycle
|
|
s-0.1s-ms-6s-ms-6sms-60s recovery
|
|
11
|
Number of times for rated short-circuit current on or off
|
times
|
30
|
|
12
|
Life
|
times
|
30000
|
|
13
|
Permanent-magnet device control voltage
|
V
|
DC 220
|