Remove Now
Cancle

11kV High Quality Power distribution SF6 Ring Main Unit Switchgear

1)Ambient temperature:-5°C-+40°C; 2)Altitude: high voltage ≤1000Meter, low voltage ≤2000Meter (technical department will design specially if exceeds); 3)Relative humidity:≤85%;

Description

  • Place of Origin: Hunan, China (Mainland)
  • Brand Name: HNAC
  • Model Number: KYN28A / XGN2 / HXGN
  • Product Name: SF6 Ring Main Unit Switchgear 11kV Switchgear
  • Frequency: 50/60 Hz
  • Rated Voltage: 3.6kV, 7.2kV, 12kV
  • Rated Current: 630A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A, 5000A
  • Applicable environmental temperature: -5°C-+40°C
  • Rated peak withstand current: 40kA, 50kA, 63kA, 80kA, 100kA, 125kA
  • Rated short-time withstand current (4s): 16kA, 20kA, 25kA, 31.5kA, 40kA, 50kA
  • Customized: Yes
  • Certificate: ISO9001/ISO14001/QHSAS18001 etc
  • Application: Power distribution

 

Operating environment: 

1)Ambient temperature:-5°C-+40°C;  

2)Altitude: high voltage ≤1000Meter, low voltage ≤2000Meter (technical department will design specially if exceeds);

3)Relative humidity:≤85%

4)Seismic intensity:≤ magnitude 8;

5)Apply to the places have no fire,no explosion danger, no serious pollution,no chemical corrosion and no violent vibration. plc control cabinet

Technical Parameter:

35KV high voltage switchgear technical parameter: KYN61-40.5

Rated voltage

kV

33~40.5KV

Rated short time power frequency withstand voltage(1min)

kV

95

Rated lighting impulse withstand voltage

kV

185

Rated current

A

1250,1600,2000

Rated short circuit breaking current

kA

25       31.5

Rated peak value withstand current

kA

63       80

 

24KV high voltage switchgear technical parameter: KYN28A-24

Rated voltage

kV

24~15KV

Rated short time power frequency withstand voltage(1min)

kV

65

Rated lighting impulse withstand voltage

kV

125

Rated current

A

630,1250,1600,2000,2500

Rated short circuit breaking current

kA

25       31.5

Rated peak value withstand current

kA

63       80

 

12KV medium voltage switchgear technical parameter: KYN28A-12 / XGN2-12 / HXGN-12

Rated voltage

kV

3.6     7.2     12

Rated short time power frequency withstand voltage(1min)

kV

24      32      42

Rated lighting impulse withstand voltage

kV

40      60      75

Rated current

A

630,1250,1600,2000,2500,3150,4000

Rated short circuit breaking current

kA

20, 25, 31.5, 40, 50

Rated peak value withstand current

kA

50, 63, 80, 100, 125

 

0.4KV low voltage switchgear technical parameter: MNS / GCS / GGD

Rated voltage

V

400     690

Rated frequency

Hz

50/60

Rated current

A

400,500,630,800,1000,1250,1600,2000,2500,3150,4000,5000,6300

 

Ring Main Unit Switchgear

Year Established:

Business Type:Manufacturer, Trading Company

Management Certifiation: