Zn28-12 Series Indoor Fixed High-Voltage Vacuum Circuit Breaker
ZN28(A)-12 series indoor high-voltage vacuum circuit breaker is a kind of three-phase indoor high-voltage switchgear of rated voltage 12kV and AC 50Hz,
Description
- Model NO.: ZN28-12
- Operation: Manual Type
- Arc-extinguishing Medium: Vacuum
- Structure: Moulded Case Circuit Breaker
- Certification: ISO9001-2000
- Function: Circuit-Breaker Failure Protection
- Specification: 12KV
- HS Code: 8535210000
- Breaking Capacity: High Voltage Circuit Breakers
- Speed: High-Speed Circuit Breaker
- Installation: Fixed
- Poles Number: 1
- Type: Circuit Breaker
- Trademark: ZHON
- Origin: Zhejiang
ZN28(A)-12 series indoor high-voltage vacuum circuit breaker is a kind of three-phase indoor high-voltage switchgear of rated voltage 12kV and AC 50Hz,
|
Item
|
Unit
|
Parameter
|
|
Rated Voltage
|
kV
|
12
|
|
Rated Current
|
A
|
630-1000
|
630-1000
|
1250-1600
|
1600-2000
|
|
1250
|
1250
|
2000-2500
|
3150
|
|
Rated Short-circuit Breaking Current
|
kA
|
20
|
25
|
31.5
|
40
|
|
Rated Short-circuit Making Current (Peak)
|
kA
|
50
|
63
|
80
|
100
|
|
Rated Peak Withstand Current
|
kA
|
50
|
63
|
80
|
100
|
|
Rated Short-time Withstand Current
|
kA
|
20
|
25
|
31.5
|
40
|
|
Rated Insulation Level
|
Power Frequency Withstand Voltage (Rated Breaking Before and After)
|
kV
|
42 (Break 48)
|
|
Lightning Impulse Withstand Voltage (Rated Breaking Before and After)
|
kV
|
75 (Break 84)
|
|
Rated Operating Sequence
|
|
O-0.3s-C O-180s-CO
|
|
Mechanical Life
|
times
|
10000
|
|
Rated Short-circuit Current Breaking Times
|
times
|
50
|
|
Rated Closing Voltage of Operator (DC)
|
V
|
110, 220
|
220
|
|
Rated Closing Current of Operator (DC)
|
A
|
71
|
128
|
|
Rated Opening Voltage of Operator (DC)
|
V
|
110, 220
|
|
Rated Opening Current of Operator (DC)
|
A
|
3.0, 1.5
|
|
Clearance Between Open Contacts
|
mm
|
11± 1
|
|
Over travel of Contacts
|
mm
|
4± 1
|
|
Three-phase Opening/Closing Synchronization
|
ms
|
≤ 2
|
|
Closing Bouncing Time
|
ms
|
≤ 2
|
|
Average Opening Speed (excluding Oil Bumper)
|
m/s
|
1.2± 0.3
|
|
Average Closing Speed
|
m/s
|
0.6± 0.2
|
|
Opening Time
|
Highest Operating Voltage
|
s
|
≤ 0.06
|
|
Lowest Operating Voltage
|
s
|
≤ 0.08
|
|
Closing Time
|
s
|
≤ 0.2
|
|
Main Loop Resistance of Each Phase
|
μ Ω
|
≤ 40
|
≤ 20
|
|
Total Thickness of Permissible Wear of Moving and Static Contacts
|
mm
|
3
|
|
Oil Bumper Buffer Trip
|
mm
|
10
|